IR Spectrometry
|
||
| InfraLUM FT-10 |
![]() |
InfraLUM FT-10 FT-NIR Analyzer is a multipurpose near-IR (8500-14 500 cm-1 ) FT spectrometer, which is designed for laboratory analysis of basic components of food products, grains, and feed mixes, such as proteins, fats, moisture, sugar, cellulose, starch, fibers, salt, etc., Determination of such biological properties of a sample as the sprouting ability of seeds, caloric content of food products, grain size, and others can be also achieved using this machine. The instrument employs the NIR-transmission technique, accommodates most of chemometrics prediction algorithms, and allows for high flexibility of analysis methods. The analyzer is controlled by a dedicated SpectraLUM/Pro software, which enables to carry out routine analyses in a very simple dialogue mode, so that even an unskilled operator can operate the instrument. Read more... |
| InfraLUM FT-20 NEW! |
![]() |
InfraLUM FT-20 FT-NIR Analyzer is a multipurpose near-IR (1000-2200 nm) FT spectrometer, which is used for fast non-destructive qualitative and quantitative analysis of powders, fibers, films, slurries, and natural products. The instrument employs FT-NIR diffuse reflectance spectrum technique with a bi-directional optical fiber probe. InfraLUM FT-20 combines the advantages of FT analysis and NIR spectroscopy. For samples packed in plastic, the InfraLum FT-20 scans the sample right through the packaging material allowing for non-destructive and non-invasive analysis of finished products in real time. The analyzer is controlled by a dedicated SpectraLUM/Pro software, which enables to carry out routine analyses in a very simple dialogue mode, so that even an unskilled operator can operate the instrument. Read more... |
Capillary electrophoresis
|
||
| CAPEL-series |
![]()
|
CAPEL-series Capillary Electrophoresis Systems. Capel-103 and its upgraded versions Capel-104 and –105 are high-performance CE instruments equipped with light sources and photometric detectors. Models 103 and 104 operate at a 254-nm wavelength, while Capel-105 is equipped with a detector and UV monochromator, covering the 190-380-nm spectral range. Capel-103 has a manualy controlled sampler with 4 inlet and 2 outlet positions, and Capel-104 and –105 have autosamplers with 10 inlet and 10 outlet positions. The samples, rinsing and buffer solutions are injected automatically by pressure or electrokinetically according to a preset program. All the instruments are equipped with capillary cassettes, containing air (103)- or liquid-cooled capillaries of 30-100-cm in length and 25-100 µm i.d., reversible polarity ±25 kV voltage supply units, and with customized report outputs (hard copy and file). The dedicated software package supports data acquisition and processing, data exchanges with worksheets, databases and word processors. The software package utilizes a standard PC and powerful Chrom&Spec software package, which makes the analysis fully automated. Read more... |
Luminescent and absorbtion photometric analysis
|
||
| Fluorat-02-series |
![]() |
Fluorat-02-series Analyzers employ the modular principle to diversify the highly sensitive and selective luminescent analysis technique. The base unit, Fluorat-02, is a filter-based fluorometer, photometer, and chemoluminometer. All these modes of operation are implemented in the same optoelectronic scheme. In addition, the Fluorat-02-2M version is a time-resolving fluorometer, which can be used as a fluorometric detector in any HPLC system. The analyzers are equipped with high-pressure xenon arc lamps, with a high-intensity light in the 200-650-nm spectral range, and are furnished with appropriate sets of light filters and measuring cells. Fluorat-02-02/3M analyzers operate in a user-friendly menu mode to analyze common contaminants, such as petroleum hydrocarbons, phenols, surfactants, formaldehyde, nitrites, nitrates, sulfides, fluorides, and a number of elements. The software package allows for saving calibration tables and background value for 16 different components in the built-in memory, and for printing out the results of analysis. These analyzers can also operate with a fiber optic cable to measure luminescence or reflected light from the surface of an outside sample, such as paper, cathodoluminophors, etc. The small (300x300x90 mm) and light-weight (8 kg) analyzers are energized from an ac mains or from a 12-V battery, which allows their use in mobile laboratories. Read more... |
| Fluorat-02-Panorama Spectrofluorometer |
![]() |
Fluorat-02-Panorama Spectrofluorometer incorporates two monochromators in the luminescence excitation and detection paths, which are arranged in a compact two-level configuration, a xenon flashlamp as a light source, and a PMT as a detector of luminescence signals. The monochromators employ 900-l/mm concave diffraction gratings with a 100-mm radius of curvature, covering the 210-730-nm spectral range. The wavelengths are set either from a built-in keypad or using a computer control program. The instrument is designed for analysis of luminescence spectra of liquid and solid samples, chromatographic analysis of several components during a single eluation, and is capable of scanning synchronous or two-dimensional spectra in both excitation and luminescence detection paths. |
Automatic Analyzers
|
||
| AKMC |
![]() |
AKMC-1 water hardness monitor is designed for stand-alone unattended continuous monitoring. The principle of operation of this instrument is based on potentiometric determination of the total content of calcium and magnesium ions (water hardness) in any natural or industrial water samples. The device may be used for monitoring at water preparation facilities and for quality control of feed water in power plants and in artesian-well water softening. AKMC-1 monitors consists of an electrochemical unit with ion-selective electrodes and a standard unit with a hydraulic unit. This design provides uninterrupted measurements of ion concentrations in real time with automatic correction for variations of temperature in the water flow. The instruments are equipped with RS-485 computer interfaces for customized report output and remote computer-aided control. Concentration measurement results, up to 1000, are stored in a built-in memory and are displayed on a built-in LCD or can be printed out. If the analysis result exceeds certain level, the alarm mode is activated, and a final-control mechanism can be automatically switched off by a command from the flow analyzer. Read more... |